Research on carbon dioxide emission and its reduction countermeasure of thermal power plants in China
According to the existing and planning scale of thermal power plants in China,combining carbon dioxide emission control of thermal power plants at present,some countermeasures have been suggested through analysis,and the quantity of emission reduction by above coutermeasures have been given.
Discussion on photovoltaic power station access network scheduling model in Qinghai province
LI Chun-lai,ZHU Hui-minIn Qinghai province,development and utilization of solar energy resources potential is enormous.According to the Qaidam basin "Million Kilowatts of Qinghai province level photo voltaic power base development planning,Qinghai province to 2010,with a total installed capacity of photovoltaic energy will reach 20 million kilowatts,2020 vision installed capacity than 750 million kilowatts,with a total installed capacity of vision in 2030 to 20 million kilowatts.However,Qinghai photovoltaic energy is also facing difficulties,such as photovoltaic station scheduling techniques,economic problems must be solved properly.Based on Qinghai photovoltaic station access network scheduling model,with the intention of working out corresponding Qinghai province power grid photovoltaic power station and the safe and stable operation and provide helpful guidance.
Research progress on carbon emission factors of coal combustion in power generation industry
LU Zhimin;CHEN Xiaoxuan;LIU Zeming;YAO Shunchun;[Objective] As a core parameter for accounting and reporting greenhouse gas emissions, the carbon emission factor of coal combustion is crucial to support China 's dual-carbon goal. Clarifying the calculation method and influencing factors of carbon emission factors in the power generation industry can guide coal-fired power units to reduce carbon emissions. [Methods] This paper systematically reviews the related research on carbon emission factors of coal combustion in power generation industry. It summarizes the different calculation methods and application status based on emission factors, analyzes the influence of key variables such as coal quality characteristics, carbon oxidation rate and calorific value on emission factors, and puts forward targeted research suggestions on carbon emission factors in power industry. [Results] The research shows that from the default value method, the measured calorific value method, the measured element method to the direct monitoring method, the accuracy of the emission factors calculated by different methods is gradually improved, but the difficulty of data acquisition is also gradually increased. Variables such as coal quality characteristics, carbon oxidation rate and calorific value all have significant effects on emission factors. From the perspective of national studies in different countries, there are great changes in carbon emission factors, among which the change of lignite carbon emission factor is the largest. The lignite emission factor in China is about 11% different from that in the European Union, 6% different from that in the United States, and the difference of lignite emission factor within the European Union is as high as 39.2%. [Conclusion] In view of the research on carbon emission factors of coal combustion in power generation industry, it is suggested to strengthen the measurement and statistics of coal quality parameters and establish a national carbon emission factor database. Promoting the development of direct monitoring technology for carbon emissions and build an accurate carbon measurement system. Establishing relevant standards to achieve a comprehensive assessment of the uncertainty of carbon measurement data and cross-validation of data.
Treatment of coking wastewater with Fenton oxidation-sedimentation
Fenton-oxidation-sedimentation was used to treat coking wastewater. The removal of COD, NH3-N, turbidity and color was mainly studied. The influence effects and conditions were investigated. The results show that the removal efficiency of COD, NH3-N,turbidity and color can reach 93.1%, 96.2%, 90.8% and 90.2% under the conditions of pH=3, oxidation time 30 min and temperature 80 ℃ respectively.
Development and application of Seawater-FGD technology with self-owned intellectual property
Beijing Longyuan Environmental Protection Engineering Co.,Ltd.undertook the National High-tech R&D Program(863 Program),named Large-sized coal-fired power station boiler Seawater-FGD technology and demonstration,and developed the Seawater-FGD technology with self-owned intellectual property.The principle and process of Seawater-FGD were describes briefly and the details of the R&D project and its demonstration were presented.The success of the Seawater-FGD technology and its practical application has important significance in realizing domestic manufacture,reducing investment and operation cost.
Numerical simulation on fuel nitrogen conversion in flameless oxy-fuel combustion of biomass-pulverized coal blends
ZHU Shichao;ZHENG Hongyu;LI Pengfei;SHI Guodong;LIU Qian;ZHOU Haoyu;LIU Zhaohui;Flameless oxy-fuel combustion significantly reduces NOx emissions and captures high concentrations of CO2,positioning it as a leading technology in clean and low-carbon combustion.Biomass,a widely available renewable energy source,can effectively reduce CO2 emissions when co-fired with pulverized coal.This study investigates the nitrogen conversion characteristics of biomass-coal blends under flameless oxy-fuel combustion through simulations conducted on a 0.58 MW combustion furnace.The simulations incorporate a reaction mechanism and radiation model suitable for oxy-fuel combustion.After verifying the model and algorithms,the study examines the fuel nitrogen conversion mechanism.The results indicate that as the biomass blending ratio increases from 0 to 100%,the low-oxygen zone in the furnace expands,and the distribution of CO widens.Additionally,the peak temperature inside the furnace rises.Specifically,when the blending ratio is 50%,the temperature increase compared to pure pulverized coal combustion is 47℃,and at a blending ratio of 70%,the increase is 55℃.For pure biomass combustion,the peak temperature reaches 1 850 K,which is 71℃higher than that of pure pulverized coal combustion.When the biomass blending ratio increases from 0 to 50%,NO reburning decreases significantly by more than 61%compared to pure coal combustion and remains relatively unchanged with further increases in the blend ratio.Despite the higher volatile content of biomass compared to coal,the total NO from volatiles remains almost constant after blending.The fixed carbon nitrogen decreases significantly after blending due to the lower fixed carbon content in biomass,leading to a reduction in NO emissions.When the blending ratio increases from 0%to 100%,NO emissions decrease by 51%.
Existing question and recommendation for the technological evaluation of Natural Draft Cooling Towers(NDCT) with flue gas injection
MO-Hua,LIU Si-meiThe present techniques of Natural Draft Cooling Towers(NDCT) with flue gas injection in overseas coal-fired power plants were introduced.The characteristics of the evaluated Natural Draft Cooling Towers(NDCT)with flue gas injection projects in domestic coal-fired power plants were elaborated.The existing question for the technological evaluation of the Natural Draft Covling Touers techniques were analyzed briefly.Some recommendation about the uncertainty of the forecasting results and the disunion perception of the environmental impact were put forword.
Study on the purification efficiency of subsurface constructed wetlands
The removal efficiencies and characteristics of two types of subsurface constructed wetlands were investigated.The applicable values in sewage treatment,especially in power plant sewage treatment,of constructed wetlands were analysed.
Research progress of noise control technology of substation
In view of the characteristics of substation noise,the noise control scheme is introduced from three aspects of noise source,noise transmission path and receiver. In the aspect of noise source control,it mainly controls the noise of the transformer body and the noise of the cooling device. In the field of noise transmission,use the sound of absorption,silencing,soundproofing and sound barrier technology; Protective earplugs are used for the protection of the receiver. The application results of these noise control measures in practical engineering are also analyzed. At the same time,the noise reduction of main transformer and ventilation fan is proposed. In order to make the noise control of the substation achieve very good effect,the measures should be taken in combination with various methods.